Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Esthet Restor Dent ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500312

RESUMO

OBJECTIVES: This laboratory study evaluated the influence of the fluorescence intensity of composite resins on additional tooth wear and the presence of restorative material in different dental thirds during the retreatment of direct veneers. MATERIALS AND METHODS: The crown dimensions of 60 bovine incisors were reduced to 10 × 8 mm. The teeth were classified according to the fluorescence intensity of the composites: low (LOW) (TPH Spectra), medium (MED) (Opallis), and high (HIGH) (Essentia) groups. The teeth were divided according to the removal methods: conventional (CON) and fluorescence-aided identification technique (FIT). The specimens were scanned (T0), received veneer preparation, and scanned again (T1). After restorations, the composites were removed and the teeth were scanned (T2). Measurement assessments between T1 and T2 were performed to determine additional wear, presence of residual areas, and the average between additional wear and the presence of residual areas. Kruskal Wallis, Mann-Whitney, Friedman, 2-way ANOVA, and post-Tukey tests were performed (α < 0.05). RESULTS: The comparison of composite resins indicated a smaller area of additional wear and greater residue presence in the HIGH group than the LOW group for both techniques in the cervical third. Regarding removal methods, the FIT produced greater additional wear than the CON method for the LOW and MED groups in the middle and cervical thirds. The incisal third exhibited greater additional wear than the other thirds. CONCLUSIONS: Composite resins with high fluorescence intensity removed using FIT had less tooth wear. The incisal third was the most affected area for direct veneer removal procedures. CLINICAL SIGNIFICANCE: A FIT has been proposed for composite resin removal; however, the different fluorescence intensities of composite resins can influence tooth wear caused during this procedure.

2.
J Photochem Photobiol B ; 253: 112878, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447252

RESUMO

PURPOSE: To investigate the influence of methylene blue (MB)-mediated antimicrobial photodynamic therapy (aPDT) and calcium hydroxide (CH) medication on the mechanical characteristics, degree of conversion (DC), quantification, and volume of gaps at the adhesive interface of glass fiber posts (GFPs) luted to distinct thirds of root canal dentin. Additionally, the microhardness (MH), elastic modulus (Eit), morphology, and chemical structure of the intraradicular dentin were assessed. MATERIALS AND METHODS: 6 experimental groups were formed by sorting 102 bovine incisors. Canals receiving deionized water irrigation as a negative control; canals receiving deionized water irrigation and filled with CH as a positive control; groups treated with CH + MB at 50 and 100 mg/L without irradiation; and groups treated with CH + MB at 50 and 100 mg/L irradiated by red laser for 60 s (660 nm; 100 mW; 6.5 J; 72 J/cm2). MH, Eit, and DC properties were evaluated for both the resin cement layer and root dentin substrate (n = 8). Volume and quantification of gaps at the bonding interface (n = 6), and dentin morphology and chemical content were investigated (n = 3). Data were analyzed using a repeated-measures 2-way ANOVA followed by Tukey post hoc analysis (α = 0.05). RESULTS: The distinct intraradicular thirds and treatment with MB-mediated aPDT, whether activated or not, in combination with CH, had a significant impact on the mechanical characteristics of the root dentin. This effect was also observed in the MH, Eit, DC, quantification, and volume of gaps at the luting interface (P < .05). In general, a higher concentration of MB, whether activated by a red laser or not, led to lower values in the mechanical properties of the root dentin, as well as in MH, Eit, and DC at the adhesive interface (P < .05). Additionally, these groups exhibited higher values for quantification and volume of gaps at the luting substrate (P < .05). Scanning electron micrographs and energy dispersive X-ray spectra showed qualitative similarity among all groups, except for the negative experimental control group. CONCLUSIONS: MB-mediated aPDT at 50 mg/L, in combination with CH, demonstrated favorable physico-chemical and mechanical characteristics in intraradicular dentin, along with satisfactory mechanical features and the adhesive interface integrity for GFPs at all intraradicular depths. CLINICAL SIGNIFICANCE: MB-mediated aPDT at a concentration of 50 mg/L combined to CH medication represents a suitable choice for photosensitization in the context of intracanal disinfection following the biomechanical procedure and prior to luting of intraradicular restorations.


Assuntos
Anti-Infecciosos , Vidro , Fotoquimioterapia , Animais , Bovinos , Fármacos Fotossensibilizantes/farmacologia , Hidróxido de Cálcio/farmacologia , Azul de Metileno/farmacologia , Cavidade Pulpar , Fotoquimioterapia/métodos , Dentina , Água , Teste de Materiais
3.
Sci Rep ; 14(1): 2860, 2024 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-38310154

RESUMO

Type 2 diabetes interferes with bone remodeling mechanisms, requiring studies to reverse this damage, and resveratrol is a polyphenol with rich properties. This study aimed to characterize the long bone morphology and peri-implant biomechanics of normoglycemic and type 2 diabetic animals treated with resveratrol. Thirty-two male Wistar rats were used and divided into normoglycemic and diabetic with or without treatment. They had the installation of implants in the tibia and treatment with oral resveratrol within 45 days. Resveratrol was responsible for weight homeostasis and decreased glycemic levels in rats with type 2 diabetes. The three-point bending testing, resveratrol showed positive effects on the biomechanics of long bones, corroborating a more resistant bone in comparison to untreated diabetics. Micro-ct revealed how bone metabolism is affected by systemic disease, decreasing bone quality. The counter-torque of normoglycemic animals showed superior osseointegration to diabetes, with no differences in the administration of the polyphenol, showing the sovereignty of the deleterious effects of the disease when there is a tissue lesion and an inflammatory picture installed. Overall, resveratrol acted positively in the etiopathogenesis of type 2 diabetes and revealed positive effects on the strength of long bones.


Assuntos
Implantes Dentários , Diabetes Mellitus Experimental , Diabetes Mellitus Tipo 2 , Ratos , Masculino , Animais , Resveratrol/farmacologia , Ratos Wistar , Diabetes Mellitus Tipo 2/patologia , Diabetes Mellitus Experimental/patologia , Osso e Ossos , Osseointegração , Tíbia/patologia , Titânio/farmacologia
4.
Odontology ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38374511

RESUMO

The aim of this systematic review and meta-analysis (SRM) was to evaluate whether bioceramic sealers have better penetration capacity in dentinal tubules and antimicrobial activity when compared to AH Plus® sealer. This SRM was recorded in the Open Science Framework database and followed the guidelines of the PRISMA 2020. Five databases were searched by two independent reviewers. Only in vitro studies that evaluated the effects of bioceramic sealers on dentinal tubule penetration and antimicrobial activity outcomes compared to AH Plus® sealer were included. Meta-analysis was conducted using R software, using the effect measure of the standardized mean difference (SMD) and inverse variance method. A modified Joanna Briggs Institute's Checklist was used for the risk of bias assessment. A total of 1486 studies were identified, and only 54 studies that fulfilled our eligibility criteria were included in this review. There was no statistical difference between the sealers evaluated for dentinal tubule penetration, in the thirds evaluated: coronal SMD 0.58 [0.14; 1.31], p = 0.12; middle SMD 0.07 [0.54; 0.39], p = 0.75; and apical SMD 0.08 [0.73; 0.56], p = 0.80. Both sealers demonstrated similar antimicrobial action (SMD [3.42; 5.32], p = 0.67 and SMD 0.67 [1.89; 0.55], p = 0.28). The studies presented a low risk of bias. Based on the in vitro studies included and according to the limitations of the present review, the data suggest that bioceramic and AH Plus® sealers present similar penetration capacity in dentinal tubules and antimicrobial effect, making them suitable materials to be considered in clinical practice.

5.
Dent J (Basel) ; 11(7)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37504240

RESUMO

PURPOSE: This study evaluates the effects of different toothpastes on the nanohardness and chemical compositions of restorative materials and dental surfaces. METHODS: Bovine enamel (n = 72) and dentin (n = 72) blocks were obtained and restored using RMGIC (n = 36) or CR (n = 36) to create the following surfaces: dentin adjacent to RMGIC (DRMGIC), enamel adjacent to RMGIC (ERMGIC), dentin adjacent to CR (DCR), and enamel adjacent to CR (ECR). After restoration, one hemiface of each specimen was coated with an acid-resistant varnish to facilitate the creation of control (C) and eroded (E) sides; the latter were achieved by erosion-abrasion cycles as follows: erosion with 1% citric acid: 5 days, four times for 2 min each day; 1% citric acid/abrasion, two times for 15 s, followed by immersion in a toothpaste slurry for 2 min. Toothpastes without fluoride (WF; n = 12), with sodium fluoride (NaF; n = 12), and with stannous fluoride (SnF2; n = 12) were used for RMGIC or CR. The specimens were analyzed for nanohardness (H), and chemical composition using energy-dispersive X-ray spectroscopy and Raman microscopy. The data were statistically analyzed using two-way repeated measures ANOVA and Tukey's test (α = 0.05). RESULTS: Lower H values were obtained with NaF for DRMGIC-C, with a statistically significant difference from the H value obtained with WF (p < 0.05). The calcium and phosphorus concentrations in DCR-E were significantly lower with WF than with the other types of toothpaste (p < 0.05). Fluoride-containing toothpastes are capable of preserving the main chemical components of the dentin adjacent to the restorative materials under erosive-abrasive conditions.

6.
J Mech Behav Biomed Mater ; 145: 106027, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37487466

RESUMO

PURPOSE: This in vitro study aimed to evaluate the aesthetic compromise generated in adhesive interface of ceramic laminate veneer luted after tooth bleaching and the use of antioxidant agents. Thus, the chromatic coordinates and whitening index (WID) were evaluated, comparing whiteness changes (ΔWID) results to perceptibility and acceptability thresholds. MATERIAL AND METHODS: In total, 88 bovine enamel samples (7 × 8 × 4 mm; n = 8) were submitted to the ceramic laminate veneer luting protocol according to surface treatment (unbleached and bleached enamel), antioxidant agents (control; 10% ascorbic acid and 10% α-tocopherol), and luting periods (after 24 h and after 14 days). To lute IPS e.max ceramic restorations (7 × 8 × 0.6 mm), Tetric N-Bond Universal adhesive system and Variolink Aesthetic LC resin cement were used. An ultraviolet-visible spectrophotometer (UV-VIS) was utilized to measure CIE L*a*b* coordinates prior to and after UV-B artificial accelerated aging for 252, 504, and 756 h. L*, a*, and b* axes were evaluated separately, and the whitening stability (ΔWID) effect was assessed by varying the whiteness index for dentistry (WID). The 50:50% visual threshold was used to evaluate ΔWID values (whiteness perceptibility [WPT] and whiteness acceptability [WAT]). Color parameters changes (ΔL*Δa*Δb*), WID, and ΔWID data were subjected to 2-way repeated measures ANOVA followed by Tukey's test (α = 0.05). RESULTS: Different UV-aging periods influenced the chromatic coordinates, WID, and ΔWID of the ceramic restorations regardless of the bleaching treatment, antioxidant solutions and luting periods (P < .05). In general, ΔWID values after UV-aging periods were above perceptibility and acceptability thresholds (WPT = 0.72 and WAT = 2.62, respectively) for all experimental groups (P < .05). Unbleached and 10% ascorbic acid-treated enamels luted after 14 days of the antioxidant action exhibited lower ΔL* and Δb* values, while control group showed lower Δa* values. All experimental groups showed similar performance on ΔWID compared to the control group, regardless of the UV-aging period analyzed (P > .05). CONCLUSION: α-tocopherol is a suitable antioxidant solution to be used 24 h post enamel bleaching not compromising clinical acceptability of ceramic laminate veneers. CLINICAL RELEVANCE: The adhesive interface of ceramic laminate veneers may appear darker after the use of antioxidant agents affecting the clinical acceptability of the restorations.


Assuntos
Antioxidantes , alfa-Tocoferol , Animais , Bovinos , Antioxidantes/farmacologia , Cor , Teste de Materiais , Cerâmica , Ácido Ascórbico
7.
Odontology ; 111(4): 793-812, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37378833

RESUMO

The aim of this systematic review and meta-analysis (SRM) was to assess postoperative pain (PP) after endodontic treatment with bioceramic root canal sealer compared to AH Plus® sealer. This SRM was carried out in accordance with the items on the PRISMA 2020 checklist and Cochrane guidelines and registered in PROSPERO (CRD42021259283). Only randomized clinical trials (RCTs) were included. Meta-analysis was conducted using R software, the standardized means difference (SMD) measure of effect was calculated for quantitative variables, and the odds ratio (OR) for binary variables. The Cochrane tool (RoB 2.0) was used to assess the risk of bias, and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach was used to assess the quality of evidence. Qualitative and quantitative analysis included 18 and 17 studies, respectively. For quantitative variables, the bioceramic root canal sealer presented less occurrence of postoperative pain than the AH Plus® sealer in 24 h (SMD - 0.17 [- 0.34; - 0.01], p = 0.0340). For binary variables, there was no difference observed between the sealers evaluated, except for sealer extrusion where the bioceramic group had lower post-filling material extrusion (OR 0.52 [0.32; 0.84], p = 0.007). Regarding the risk of bias analysis, low risk was observed for most domains, except allocation that was considered unclear, while the certainty of evidence ranged from moderate to low. The results showed that bioceramics sealers reduced postoperative endodontic pain only after 24 h and showed less sealer extrusion compared to the AH Plus® sealer. However, more robust and standardized clinical trials are needed to confirm the results with less heterogeneity and higher quality of evidence.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Resinas Epóxi , Cavidade Pulpar , Ensaios Clínicos Controlados Aleatórios como Assunto , Obturação do Canal Radicular/métodos , Dor Pós-Operatória/prevenção & controle
8.
J Mech Behav Biomed Mater ; 143: 105934, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37257313

RESUMO

The aim of this study was to evaluate the influence of various opacities and thicknesses of lithium disilicate on the degree of conversion (DC) of two resin cements and on their bond strength (BS) to the ceramic. Two hundred and forty ceramic samples of lithium disilicate with high translucency (HT), low translucency (LT), and medium opacity (MO) were obtained from IPS e. max CAD in five different thicknesses. Light-cured and dual-cured resin cements were used for DC (n = 9) and BS (n = 8). Cement samples were light-cured under ceramic samples and analyzed using a Raman confocal spectrometer to determine the DC. For BS, resin cement cylinders were fabricated using ceramic samples which were thsen subjected to a microshear bond strength test. The mean values were provided for statistical analysis. The increase in thickness resulted in a decrease in DC for both cements under all experimental conditions, but only affected the BS of the light-cured cement for the MO ceramic. Comparing the opacities, the most translucent ceramics with particular thicknesses exhibited higher DC values than the less translucent ceramics. The LT and MO ceramics with certain thicknesses exhibited the highest BS values than the HT. The dual-cured cement generally showed highest values in both analyses than the light-cured cement. A thicker and more opaque ceramic material can reduce the DC of the cement. The BS decreases with the increasing thickness of the more-opaque ceramics.


Assuntos
Porcelana Dentária , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Cerâmica/química , Propriedades de Superfície
9.
J Mech Behav Biomed Mater ; 141: 105757, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36924612

RESUMO

PURPOSE: This in vitro study evaluated the influence of antimicrobial photodynamic therapy (aPDT), using methylene blue (MB) as photosensitizer (PS) and calcium hydroxide (CH) as intracanal medication on adhesive bond strength, sealing, and integrity of the luting interface of glass-fiber posts to different thirds of endodontically treated root canal dentin. MATERIAL AND METHODS: 102 incisors were sorted into 6 groups: a negative control irrigated with deionized water; a positive control irrigated with deionized water and filled with CH; CH + MB 50 mg/L without laser radiation; CH + MB 100 mg/L without laser radiation; CH + MB 50 mg/L radiated by red laser; and CH + MB 100 mg/L radiated by red laser. Push-out bond strength (n = 8), adhesive interface sealing (n = 3), and volume and quantification of voids (n = 6) were assessed using a universal testing machine, confocal laser scanning microscope, and computerized microtomography, respectively. Scanning electron micrographs were obtained from representative samples to qualify the fracture patterns. Push-out bond strength and adhesive interface integrity data were subjected to 2-way ANOVA for repeated measures followed by Tukey's test (α = 0.05). Adhesive interface sealing was evaluated by the inter-examiner Kappa test and submitted to Kruskal-Wallis and Dunns tests (α = 0.05). RESULTS: Assessing the apical region, the positive control and MB100WA + Ca(OH)2 groups showed lower adhesive bond strength compared to the MB100A + Ca(OH)2 group (P < 0.05). The cervical third showed higher bond strength than the apical third for the positive control, MB50WA + Ca(OH)2, MB100WA + Ca(OH)2, and MB50A + Ca(OH)2 groups (P < 0.05). A prevalence of mixed failure was observed in all experimental groups. There were no statistically significant differences in adhesive interface sealing for any of the parameters assessed (P > 0.05). MB100WA + Ca(OH)2 and MB100A + Ca(OH)2 groups promoted a higher volume and quantification of voids compared to the negative control group evaluating the cervical third (P < 0.05). In general, there were no differences in the quantification of voids comparing the intraradicular thirds (P > 0.05), differently to the volume of voids in which, in general, the cervical third promoted higher values compared to the middle and apical thirds (P < 0.05). CONCLUSION: aPDT with methylene blue PS at 50 mg/L associated with calcium hydroxide as intracanal medication demonstrated satisfactory bond strength, sealing, and integrity of the adhesive interface at any intraradicular depth.


Assuntos
Colagem Dentária , Fotoquimioterapia , Hidróxido de Cálcio , Adesivos , Azul de Metileno , Fotoquimioterapia/métodos , Vidro/química , Dentina , Água , Teste de Materiais , Cimentos de Resina/química
10.
Clin Oral Investig ; 27(4): 1343-1361, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36757461

RESUMO

OBJECTIVE: The objective of this systematic review and meta-analysis (SRM) was to answer the question as to whether the use of ultrasonic irrigation (UI) results in better antimicrobial activity in root canal disinfection compared to conventional irrigation (CI). METHODS: A literature search was performed in the main scientific databases, carried out until October 2021. The eligibility criteria were randomized clinical trials (RCTs). Two meta-analyses were conducted using R software with the "META" package. The mean difference (MD) and odds ratio (OR) measure of effect were calculated. The fixed effect model was applied with a 95% confidence interval. The Cochrane collaboration scale was used to assess risk of bias and the GRADE tool to assess the quality of evidence. RESULTS: A total of 1782 records were screened, and 12 studies meeting the criteria were included in this review. A low risk of bias was observed for most domains, except allocation concealment that was considered unclear. The certainty of evidence was classified as moderate in the OR meta-analyses and low in the MD meta-analyses. Ultrasonic irrigation resulted in a better antimicrobial effect in both meta-analyses, MD 1.42 [1.60; 1.23] p < 0.0001, I2 = 80%; and OR 3.86 [1.98; 7.53] p< 0.0001, I2 = 28.7%. CONCLUSION: Within the limitations of this SRM, UI presented better antimicrobial efficacy than CI. CLINICAL RELEVANCE: UI should be used by clinicians as it promotes better antimicrobial efficacy in patients undergoing endodontic treatment.


Assuntos
Anti-Infecciosos , Irrigantes do Canal Radicular , Humanos , Cavidade Pulpar , Ensaios Clínicos Controlados Aleatórios como Assunto , Irrigantes do Canal Radicular/farmacologia , Ultrassom/métodos
11.
J Prosthodont Res ; 67(1): 103-111, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35264548

RESUMO

PURPOSE: The structural integrity of the resin cement layer, the bond strength, and the biomechanical behavior of different fiberglass post cementation techniques were evaluated. METHODS: Thirty-three bovine incisors were divided into three groups (n = 11): conventional fiberglass post (CFP), conventional fiberglass post in flared root canals (CFL), and relined fiberglass post (RFP). Six specimens from each group were submitted for high-resolution microcomputed tomography (µCT) to evaluate the integrity and presence/volume of voids at the resin cement layer. Finite element analysis (FEA) of two three-dimensional (3D) models of each group were conducted, one considered ideal (without interface defects) and another containing the conditions identified in the µCT analysis. Push-out bond strength tests were conducted for all specimens. RESULTS: The CFL group had the greatest mean values of void (Thirds cervical: 73.67; middle: 95.67; apical: 47.33) and gap concentration (Thirds cervical: 14.67; middle: 15.83; apical: 8.33) compared with CFP and RFP. A significant difference in bond strength was observed between the cervical (1.33 MPa) and middle thirds (1.85 MPa) compared with the apical third (4.85 MPa) of the CFL. A significant difference was observed in the bond strength in the CFL (1.33 MPa) and RFP (3.29 MPa) in the cervical third, which were statistically similar to the bond strength of the CFP. The tensile stress distributions were similar in most structures, localized in the cervical region on the lingual surface. CONCLUSIONS: Structural defects in the interface layer might influence the bond strength and biomechanical behavior under the different fiberglass post cementations.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Animais , Bovinos , Cimentação/métodos , Cimentos de Resina/química , Microtomografia por Raio-X , Vidro/química , Dentina , Teste de Materiais
12.
Photodiagnosis Photodyn Ther ; 39: 103014, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35840008

RESUMO

BACKGROUND: To evaluate the effectiveness of the use of antimicrobial photodynamic therapy (aPDT) in root canals disinfection in cases of endodontic retreatments. METHODS: This Systematic Review was registered in PROSPERO (CRD42021260013) and followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Searches were performed in the electronic databases PubMeb, Scopus, Web of Science, Embase, Web of Science, Clinical Trials and Cochrane Library. Methodological quality and risk of bias were assessed by the Cochrane Risk of Bias tool for randomized clinical trials (RCT) and by the Newcastle-Ottawa (NOS) qualifier for non-RCT (prospective) studies. Meta-analysis was performed using R software, version 3.6.3 with the "META" package assistant by the RStudio platform. The odds ratio (OR) measure of effect was calculated and the random effect model was applied with a 95% confidence interval, and heterogeneity tested by the I2 index. The certainty of evidence was rated using GRADE. RESULTS: Regarding the 1513 studies screened, 10 met the eligibility criteria and were included, and 8 used in the quantitative synthesis. Meta-analysis showed that all of studies data presented a significant difference before and after of antimicrobial photodynamic therapy in the microbial load reduction in secondary endondontic infections (OR 0.15 [0.07; 0.32], p < 0.0001). Overall, the studies had a low risk of bias and, the analysis of evidence by GRADE assessment was rated as moderate. CONCLUSION: It is suggested that aPDT is a beneficial and promising tool, showing efficacy in reducing the microbial load in cases of endodontic retreatment.


Assuntos
Anti-Infecciosos , Fotoquimioterapia , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Desinfecção , Fotoquimioterapia/métodos
14.
J Mech Behav Biomed Mater ; 133: 105322, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35724532

RESUMO

PURPOSE: This in vitro study aimed to determine the effect of antioxidant solutions used after dental bleaching on the shear bond strength and adhesive interface sealing of ceramic laminate veneer luting. Additionally, effects on the enamel surface characteristics of hydrogen peroxide neutralization, surface energy, total free interaction energy, morphology, and chemical composition of enamel were assessed. MATERIAL AND METHODS: Total 127 bovine incisors were divided into experimental groups, according to the surface treatment (unbleached and bleached enamel), antioxidant types (control; 10% ascorbic acid and 10% α-tocopherol), and periods of luting of ceramic laminates (24 h and after 14 days). Shear bond strength was assessed using microtensile test before and after thermal cycling (5760 cycles, 5-55 °C) (n = 6). The sealing of the adhesive interface was assessed using a confocal laser scanning microscope (n = 3). Hydrogen peroxide neutralization analysis was performed using a spectrophotometer (n = 5). The surface energy and total free interaction energy (n = 10) were measured using an automatic goniometer, while enamel morphology and chemical composition were assessed by scanning eletron microscopy (n = 3). Shear bond strength and enamel surface properties data were subjected to ANOVA followed by Tukey's test (α = 0.05). Adhesive interface micrographs were evaluated by the inter-examiner Kappa test and subjected to Kruskal-Wallis and Dunn's tests (α = 0.05). RESULTS: In general, thermal aging decreased the shear bond strength values of the luting agents to enamel (P < .05). The α-tocopherol solution was able to reverse the oxidizing effect from dental bleaching, increasing the shear bond strength values and preserving the integrity of the adhesive interface sealing (P < .05). Moreover, the α-tocopherol antioxidant agent promoted higher hydrogen peroxide neutralization after dental bleaching (P < .05). Dental bleaching influenced the enamel surface, decreasing the surface energy and total free interaction energy values (P < .05). CONCLUSION: α-tocopherol was able to reverse the oxidizing effects of dental bleaching, improving the enamel surface properties, as well as the adhesion and interface sealing of ceramic laminate veneer restorations.


Assuntos
Antioxidantes , Colagem Dentária , Animais , Antioxidantes/farmacologia , Bovinos , Cerâmica/química , Resinas Compostas/química , Esmalte Dentário , Análise do Estresse Dentário , Peróxido de Hidrogênio , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , alfa-Tocoferol/farmacologia
15.
Inquiry ; 59: 469580221095824, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35549576

RESUMO

In the midst of the pandemic caused by the new coronavirus (SARS-CoV-2), researchers and governmental and non-governmental institutions are mobilizing to implement strategies to face cases of COVID-19. Aim: This study aimed to map the triage strategies for cases of COVID-19, with the purpose of identifying sources in the literature that make it possible to explore the understanding of the strategies in different contexts. A scope review was conducted with searches in the CINAHL Database, PubMed, LILACS and hand-search, considering studies carried out with users of health services and documents published by governmental and non-governmental institutions, between the years 2019 and 2020, resulting in 40 articles for full reading. To explore the key concept, thematic analysis was carried out at two levels: (1) triage strategies, (2) forms and experiences of triage. Five triage strategies were mapped: health services triage; digital triage by remote use of technologies; community triage; home visit triage and airport and port triage. The forms and experiences of mapped triages involved risk classification, diagnosis and definition of conducts or combined. The use of strategies with remote technological resources stands out, as well as the adaptation of existing scales with simple algorithms as a tendency.


Assuntos
COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Triagem
16.
Clin Oral Investig ; 26(9): 5697-5710, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35556174

RESUMO

OBJECTIVES: This randomized, prospective, and split-mouth study aimed to evaluate flowable bulk-fill resin composites in class II restorations, comparing it with a conventional layering technique after 4-year follow-up. MATERIALS AND METHODS: Fifty-three subjects received three class II restorations according to the restorative systems: conventional microhybrid composite resin (PA - Peak Universal + Amelogen Plus, Ultradent); flowable bulk-fill and nanoparticulate composite resins (ABF - Adper Single Bond 2 + Filtek Bulk Fill Flow + Filtek Z350XT, 3M/Espe); and flowable bulk-fill and microhybrid composite resins, (XST - XP Bond + SDR + TPH3, Dentsply). The clinical performance and interproximal contacts were evaluated. Statistical analyses were performed using the Kaplan-Meier, equality test of two proportions, Friedman, Wilcoxon, Kruskal-Wallis, Mann-Whitney, and Logistic regression analysis tests (alpha = 0.05). RESULTS: In total, 106 restorations were evaluated at 4 years. Both systems with bulk-fill composites presented higher marginal discoloration than PA. About surface texture, ABF restorative system showed superior bravo scores being statistically similar to XST. Better performance for wear and surface staining was found for XST restorative system. All restorative systems resulted in the decreased interproximal contacts, occurring early for XST. CONCLUSIONS: The restorative systems that used flowable bulk-fill resin composites showed satisfactory clinical performance compared with conventional resin composite after 4 years. All restorative systems had decreased proximal contact after 4 years. CLINICAL RELEVANCE: Initial marginal discoloration was observed in more than 50% of class II restorations performed with restorative systems that used flowable bulk-fill resin composite. All restorative systems had decreased proximal contact strength over time.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Restauração Dentária Permanente/métodos , Seguimentos , Humanos , Metacrilatos , Estudos Prospectivos
17.
Clin Oral Investig ; 26(4): 3343-3356, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35091819

RESUMO

OBJECTIVE: The objective of this systematic review and meta-analysis (SRM) was to answer the question whether the use of ultrasonic irrigation (UI) results in less postoperative pain (PP) compared to conventional irrigation (CI). METHODS: A literature search was performed within the main scientific databases carried out until May 2021. The eligibility criteria were randomized clinical trials (RCTs). Meta-analysis was conducted using R software with the "META" package, the mean difference (MD) measure of effect was calculated, and the fixed effect model was applied with a 95% confidence interval (CI). The Cochrane collaboration scale was used to assess risk of bias and the GRADE tool to assess the quality of evidence. RESULTS: Six RCTs were included for systematic review and four for meta-analysis. UI resulted in less PP in 3 of 5 periods, at 6 h (MD - 1.40 [CI - 2.38 to - 0.42] p = 0.0052), 24 h (MD - 0.73 [CI - 1.07 to - 0.39] p = 0.0001), and 48 h (MD - 0.36 [CI - 0.59 to - 0.13] p = 0.022). However, PP showed no significant differences between the groups at 72 h and 7 days (p > 0.05). A low risk of bias was observed for most domains, except allocation that was considered unclear. The certainty of evidence was classified as moderate (24 h, 48 h, and 7 days) and low (6 and 72 h). CONCLUSION: Within the limitations of this SRM, UI presented less occurrence of PP than CI. Further randomized clinical trials are needed to corroborate these findings. CLINICAL RELEVANCE: UI should be used by clinicians as it reduces postoperative pain in patients undergoing endodontic treatment.


Assuntos
Cavidade Pulpar , Ultrassom , Humanos , Dor Pós-Operatória/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Tratamento do Canal Radicular
18.
Photodiagnosis Photodyn Ther ; 37: 102650, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34838697

RESUMO

BACKGROUND: Photodynamic therapy with photosensitizers can reduce the microbial load. However, few studies have evaluated the effects of photosensitizers on the color stability of endodontically treated intraradicular dentin. This in vitro study investigated the effects of methylene blue and curcumin photosensitizers used in photodynamic therapy on the color stability of intraradicular dentin. METHODS: Sixty human incisors were divided into three experimental groups according to the photosensitizer solutions used and their concentrations: methylene blue (25 mg/L), curcumin (1000 mg/L), and curcumin (1500 mg/L). The color stability of endodontically treated intraradicular dentin was evaluated using a portable reflectance spectrophotometer before and after the samples been storage in 2 mL of the photosensitizer solutions during 5 min (n = 20). Color stability data were subjected to a normality test, and statistical analysis was performed using the one-way analysis of variance and Tukey least significant difference test (α = 0.05). RESULTS: Samples treated with 25 mg/L methylene blue photosensitizer showed a higher level of color alteration than those stored in 1000 mg/L curcumin (p = .03322). However, there was no significant difference in the color alteration profiles between the samples treated with 25 mg/L methylene blue and 1500 mg/L curcumin (p = .36428). Furthermore, there was no difference in the color alteration profiles between the dentin samples immersed in 1000 mg/L and 1500 mg/L curcumin photosensitizer solutions (p = .45321). CONCLUSIONS: Methylene blue and curcumin photosensitizers influenced the color stability of endodontically treated intraradicular dentin, and this color alteration exceeded the clinical acceptability threshold. Samples treated with 25 mg/L methylene blue showed the highest level of color alteration.


Assuntos
Curcumina , Fotoquimioterapia , Curcumina/farmacologia , Dentina , Humanos , Teste de Materiais , Azul de Metileno/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia
19.
Clin Oral Investig ; 26(3): 2527-2536, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34654942

RESUMO

OBJECTIVES: Although bleaching therapy is considered a dose-dependent treatment, the effect of the volume of product used is yet to be studied. This study thus aimed to evaluate the influence of bleaching gel volume on chromatic alteration and postoperative sensitivity. METHODOLOGY: Thirty patients were selected and allocated into three groups; the lower canines were analyzed according to the volume of gel used: GI-0.025 mL, GII-0.05 mL, and GIII-0.10 mL. Chromatic alteration analysis was performed using a portable digital spectrophotometer by calculating the ΔE, ΔE00, ΔL*, Δa*, and Δb* values and the whiteness index (WID). Spontaneous sensitivity was assessed using a questionnaire, and sensitivity was stimulated by thermo-sensory analysis. Analyses were conducted in five stages: baseline, after 1st, 2nd, and 3rd bleaching sessions, and 14 days after the end. Data were analyzed using the two-way ANOVA test with repeated measures and Tukey's post hoc test (p < 0.05). RESULTS: It was observed that ΔE, ΔE00, and ΔL* were similar between groups at the end of the bleaching therapy; and the values of Δa*, Δb*, and WID were higher in the GIII group. For sensitivity, it was found that the GI was the one with the lowest values; o GII intermediate values; while the GIII group presents the highest values of spontaneous and stimulated sensitivity. CONCLUSION: Gel volume influenced the response to bleaching and significantly influenced the spontaneous sensitivity and cold stimulus. CLINICAL RELEVANCE: The amount of bleaching gel used during therapy is key to both the response to color change and postoperative sensitivity.


Assuntos
Clareadores Dentários , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio , Ácido Hipocloroso , Espectrofotometria , Clareadores Dentários/uso terapêutico
20.
J Prosthet Dent ; 127(5): 759-764, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33454110

RESUMO

STATEMENT OF PROBLEM: Redesigned mixing tips, promising less impression material waste, have been marketed. However, whether their use adversely affects the dimensional stability and detail reproduction of the impression material is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the dimensional stability, detail reproduction, and material waste of different polyvinyl siloxane impression materials (regular and light-body) mixed with 2 different mixing tips (MIXPAC T-Mixer mixing tip and MIXPAC helical mixing tip). MATERIAL AND METHODS: Six different polyvinyl siloxane impression materials were used in 2 different consistencies: Virtual Monophase and Virtual Light Body (Ivoclar Vivadent AG), Express XT Regular and Express XT Light Body (3M ESPE), and Panasil initial contact Regular and Panasil initial contact Light (Kettenbach). The polyvinyl siloxane impression materials were mixed with 2 different mixing tips: conventional helical and T-Mixer (n=10). The specimens were prepared in a metal matrix as per specification #19 of the American National Standards Institute/American Dental Association (ANSI/ADA) and International Organization for Standardization (ISO) 4823:2015. The materials were mixed with both mixing tips as per the manufacturer's instructions, inserted into a perforated custom tray on the matrix, and allowed to polymerize completely. The dimensional stability was calculated based on the measurement of the reproduction of lines engraved in the metal matrix. Detail reproduction was evaluated through analysis of continuity and reproducibility of those lines, immediately, 7 days, and 14 days after polymerization. Material waste was assessed by the difference between the initial (before mixing) and final weight (after complete polymerization) of both mixing tips. The data on dimensional stability and detail reproduction among the materials were submitted to the Kruskal-Wallis test, followed by the Student-Newman-Keuls test (α=.05). Comparison between the mixing tips was carried out with the Mann-Whitney test (α=.05), while the comparison among the periods of analysis (immediate, 7 days, and 14 days) was carried out with the Friedman test (α=.05). The data on material waste between the mixing tips were submitted to 1-way ANOVA, followed by the Tukey honestly significant difference tests (α=.05). RESULTS: The T-Mixer mixing tip resulted in reduced material waste. For dimensional stability, Virtual Light mixed with T-Mixer resulted in lower dimensional change (0.53 ±0.58%) compared with the helical mixing tip (1.09 ±0.43%). Among the materials, Panasil Light presented higher values of dimensional change at immediate and 7-day analysis when mixed with T-Mixer tip with a statistical difference compared with Express Light, Virtual Light, and Panasil Regular (P<.05). In general, both mixing tips provided similar results in all periods of analysis (P>.05) for qualitative analysis of detail reproduction. CONCLUSIONS: The T-Mixer tip resulted in less material waste compared with the helical mixing tip. In general, light-body materials showed higher dimensional stability when the T-Mixer tip was used compared with the conventional tip. In general, reduced detail reproduction was observed after periods longer than 7 days after impression making.


Assuntos
Materiais para Moldagem Odontológica , Siloxanas , Técnica de Moldagem Odontológica , Humanos , Teste de Materiais , Polivinil , Reprodutibilidade dos Testes , Reprodução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...